33.
10
MOD GREEN
O
Pin 10 is connected to the emitter of photo coupler
for MOD GREEN function
11
INTERLOCK_D
I
Pin 11 indicates the disconnection of interlock
12
INTLK COM_D
-
The return pin for INTERLOCK_D
13
NET GREEN
O
Pin 13 is connected to the emitter of photo coupler
for NET GREEN function
14
MOD AMBER
O
Pin 14 is connected to the emitter of photo coupler
for MOD AMBER function
15
NET AMBER
O
Pin 15 is connected to the emitter of photo coupler
for NET AMBER function
Note 6.5: Precaution for external connection
Port of Digital Signal Input
To control the input signal, a switch is utilized between the ports and isolated ground.
Open Floating
Close Grounding
Port of digital Signal output
The internal resistance of the ports is 5.1 kohm, and a pull-up power supply V
pull-up
is
required with a 5.1 kohm resistor.
Initial > 0.9 * V
pull-up
Trigger < 0.5 * V
pull-up
+ 1 V
If V
pull-up
is connected to “+15V_ISO” supplied by pin18 with a 5.1 kohm resistor, initial state
would be high than 13.5 V and trigger state would be lower than 8.5 V.
Analog Signal Input Port
An isolated amplifier is utilized in the ports. The voltage level is 0 to 10 V for user to enter
the command and shall not greater than 12 V.
Analog Signal output Port
An isolated amplifier is utilized in the ports. The voltage level is 0 to 10 V for users to read
out the output values of voltage, current, and power.