6.
3.2. Electrical Specification
Table 3.2 Electrical Specification
208V
AC
± 10% (Three Phase)
Input Current (Per Phase)
5.5A
RMS
nominal per phase
Measured at the DC output
Measured at the DC output
Measured at the DC output
Rated output power at DC 1000V
1% of command setting or 0.25%
of full scale voltage between
output and command
Within operation range at 25 ˚C
At DC Mode
1% of command setting or 0.25%
of full scale current between
output and command
Within operation range at 25 ˚C
At DC Mode
D-sub Monitor/Command
(Analog Interface) Accuracy
1% of full scale rating between
output and D-sub
1000Vdc to 1900Vdc
100Vdc increments
20˚C to 40˚C
Variation in regulated output
5K~400KHz, 5KHz increments
0.4us to 10us, 0.1us increments
Allowable reverse time is limited
for a given frequency
Output power repeatability of the
DC inverter from run to run at a
constant set-point is 0.1% from
10% to 100% of rated power.