2
Remember that the unit has a high leakage current. The PE conductor MUST
be connected prior to commencing operation.
WARNING:BURN HAZARD!
The unit may reach very high temperatures and the device surface can
become quite hot. Sufficient cooling is necessary for optimal yield.
1.3 Validity
This user manual describes the installation process, maintenance, technical
data and safety instructions of the following solar inverter models under the
DELTA brand.
• RPI H3A
• RPI H4A
• RPI H5A
1.4 Product Description
This device is a single-phase grid-tie solar inverter. It converts direct current
(DC) electricity from the PV array into single-phase alternating current (AC) to
feed the excess generated power back to the local grid.
This inverter allows for a wide voltage input range (100~550VDC) and has a
high performance efficiency and user friendly design and operation. In addition,
the special DSP (Digital Signal Processor) design reduces the complexity of
the circuit and electronic components. Please note that this device does not
support off-grid function. The features for RPI H3A / H4A / H5A are shown
below.
Features
• Power Rating: 3kVA (RPI H3A), 4kVA (RPI H4A), 5kVA (RPI H5A)
• Single–phase (L + N + PE), Grid-tie, transformerless solar inverter
• Maximum efficiency: >97.5%
• Europe efficiency: 96.8% (RPI H3A) , 97.0%(RPI H4A), 96.8%(RPI H5A)
• Reactive power capability (Cap 0.8 – Ind 0.8)
• Total harmonic distortion (THD < 3%) @ full load
• 2 MPP Trackers
• 16×2 monochrome LCD display