28
Pr.23
Jog Frequency
Parameter # 23
Parameter Name
Jog frequency select
Factory Setting
d006.0 Hz
Units
0.1 Hz
Parameter value
d000.1 - d400.0 Hz
This parameter can be programmed while the drive is running.
This parameter is used to set the AC drive jog frequency. Upon receipt of a jog
command the drive will ramp to the jog frequency.
Time
Speed
Decel
Time
Accel
Time
Pr.14
Pr.14
Pr.23
JOG frequency
JOG command
ON
Operating and Protective Functions Setting
Pr.24
REV Run Setting
Parameter # 24
Parameter Name
REV run
Factory Setting
d0000
Settings
d0000 REV run enabled
d0001 REV run disabled
This parameter determines whether the AC Drive can operate in the reverse
direction.
Call 1(800)985-6929 for Sales
Call 1(800)985-6929 for Sales