The default for the frequency source and operation source is for AUTO mode. It returns to AUTO
mode whenever you cycle power. If you use a multi-function input terminal to switch AUTO /
HAND mode, the multi-function input terminal has the highest priority. When the external terminal
is OFF, the drive does not accept any operation signal and cannot execute JOG.
Digital Keypad STOP Function
Default: 0
Settings 0: STOP key disable
1: STOP key enable
This parameter is valid when the digital keypad is not set as the operation source (Pr.00-21 ≠ 0).
When Pr.00-21 = 0, the STOP key on the digital keypad is not affected by this parameter.
Display Filter Time (Current)
Default: 0.100
Settings 0.001–65.535 sec.
Minimizes the current fluctuation displayed by digital keypad.
Display Filter Time (Keypad)
Default: 0.100
Settings 0.001–65.535 sec.
Minimizes the value fluctuation displayed by digital keypad.
Software Version (Date)
Default: #####
Settings Read only
Displays the current drive software version by date.