Chapter 11 Summary of Parameter SettingsME300
11-30
Pr. Explanation Settings Default
07-33 Auto-restart interval of fault 0.0–6000.0 sec.
60.0
07-43 Average PWM signal 1–100 times 1
07-44 PWM signal period 1–2000 ms 1
07-62 dEb gain 0–65535 8000
07-71
Torque compensation gain
(motor 2)
IM: 0–10 (when Pr.05-33 = 0)
PM: 0–5000 (when Pr.05-33 = 1 or 2)
1
07-72
Slip compensation gain
(motor 2)
0.00–10.00 (default value is 1 in SVC mode) 0.00