Chapter 12 Description of Parameter SettingsME300
12.1-02-19
Example:
When Pr.02-51 displays 0009h (hex) (that is, the value is 9 (decimal) and 01001 (binary)), it
means that Relay and MO1 are ON.
Display the Frequency Command Executed by the External Terminal
Default: Read only
Settings Read only
When you set the source of the Frequency command as the external terminal, if Lv or Fault
occurs, the external terminal Frequency command is saved in this parameter.
Level of Preheating DC Current
Default: 0
Settings 0–100 %
This parameter controls the level of the preheating DC current input to the motor. The percentage
of the preheating DC current equals to the percentage of motor rated current (Pr.05-01).
Therefore, when you set this parameter, increase the level slowly to reach the desired preheating
temperature.
Related parameters: 02-73 Preheating DC Current Duty Cycle, 02-13 and 16 Multi-function
Output Relay 69: Indication of Preheating Function, 02-01–05 Multi-function Input Terminal 69:
Auto-activate preheating function.
Preheating DC Current Duty Cycle
Default: 0
Settings 0–100 %
This parameter is to set up the duty cycle of the preheating DC current input to the motor. 0–
100% corresponds to 0–10 sec. If the setting is 0%, there is no output current from the motor
drive. If the setting is 100%, there is continuous output DC current. For example, when the
setting of this parameter is 50%, the cycle time is the time spent to input current to motor for 5
seconds and stop inputting for 5 seconds. When MI #69 is enabled, this parameter operates
periodically with MI#69 until the motor drive starts to run the motor or until MI#69 is disabled.
Preheating function works only when the setting value for Pr.02-72 and Pr.02-73 are not 0.
When MI=69 (auto-activate preheating function) is enabled, MI=69 controls the start and stop of
preheating function.
When MI=69 is DISABLED, the preheating function starts after:
The motor drive stops its first operation. The motor drive cycles the power.