Chapter 12 Description of Parameter SettingsME300
12.1-06-9
Fault Record 1
Fault Record 2
Fault Record 3
Fault Record 4
Fault Record 5
Fault Record 6
Default: 0
Settings 0: No fault record
1: Over-current during acceleration (ocA)
2: Over-current during deceleration (ocd)
3: Over-current during constant speed (ocn)
4: Ground fault (GFF)
6: Over-current at stop (ocS)
7: Over-voltage during acceleration (ovA)
8: Over-voltage during deceleration (ovd)
9: Over-voltage during constant speed (ovn)
10: Over-voltage at stop (ovS)
11: Low-voltage during acceleration (LvA)
12: Low-voltage during deceleration (Lvd)
13: Low-voltage during constant speed (Lvn)
14: Low-voltage at stop (LvS)
15: Phase loss protection (orP)
16: IGBT over-heat (oH1)
18: TH1 open: IGBT over-heat protection error (tH1o)
21: Drive over-load (oL)
22: Electronic thermal relay protection 1 (EoL1)
23: Electronic thermal relay protection 2 (EoL2)
24: Motor PTC over-heat (oH3)
26: Over-torque 1 (ot1)
27: Over-torque 2 (ot2)
28: Low current (uC)
31: Memory read-out error (cF2)
33: U-phase current detection error (cd1)
34: V-phase current detection error (cd2)
35: W-phase current detection error (cd3)
36: Clamp current detection error (Hd0)
37: Over-current detection error (Hd1)
40: Auto-tuning error (AUE)
41: PID feedback loss (AFE)
. 48: Analog current input loss (ACE)
49: External fault input (EF)