LCC_LCD1-16/51 Oven Owner’s Manual C244, 320207, REV B
©2021 ITW EAE. All rights reserved. Despatch is a registered trademark in the U.S. and other
countries. No part of the contents of this manual may be reproduced, copied or transmitted in any form
or by any means without the written permission from ITW EAE - Despatch, unless for purchaser's
personal use.
2.5. Temperature
Table 4. LCC/LCD Series Oven Temperature Ranges
Time to
Temperature
(approximate
minutes)
(no load)
Cooling Time to
Temp
Minutes
(No Load)
4
Temperature
Uniformity at
6
Maximum
Operating
Temperature
For LCD & LLD only, LCC & LLC maximum temperature: 260°C.
Minimum operating temperatures and cooling times are based on a 20°C ambient temperature measured at the
fresh air inlet.
Based on cooling water supplied at 2 GPM (7.6 LPM), 16°C for nitrogen atmosphere units.
Uniformity figures are based on a nine-point test conducted in an empty oven with thermocouples connected at
3 inches (7.6 cm) from walls after the oven temperature has reached stabilization. Uniformity can vary slightly
depending on unit and operating conditions. Class 100 HEPA filtration will limit ramp rates.
Requires water cooling be activated for minimum temp rating and operation below 85°C.