C244, 320207, REV B LCC_LCD1-16/51 Oven Owner’s Manual
40 of 82
©2021 ITW EAE. All rights reserved. Despatch is a registered trademark in the U.S. and other
countries. No part of the contents of this manual may be reproduced, copied or transmitted in any form
or by any means without the written permission from ITW EAE - Despatch, unless for purchaser's
personal use.
Caution!
Design the drain system to prevent operator injury from high
temperature or pressure buildup. Piping must be able to
withstand short periods of up to 260°C (500°F) for LCC and 350°C
(662°F) for LCD ovens. Insulate drain lines and/or install warning
labels stating the potential high temperature or pressure hazard.
5.2.3. Exhaust Connections
The LCC/LCD Series oven exhaust port is located on the rear of the oven (Figure
12). Table 6 lists the requirements for the exhaust stack for the LCC/LCD Series
oven.
Figure 12. Exhaust Connections.
Notice
Do not cover cabinet cooling fan. The cooling fan is required for
lower compartment ventilation.
All stacks must comply with state and local building codes to
insure that surrounding combustible surfaces are below 71°C
(160°F).
Exhaust Opening