Cleanup
15
Cleanup
Cleanup
Cleaning the portable airless sprayer after each
use results in a trouble free start up the next
time the sprayer is used.
Cleaning from a Pail
For short term shutdown periods (over-
night to two days) refer to Short Term
Storage, page 17.
See Cleaning Fluid Compatibility,
page 20 for information on flush-
ing/cleaning fluids and Static Ground-
ing Instructions (Oil-Based
materials), page 20.
1.
Perform Pressure Relief Procedure,
page 9.
2.
Remove spray tip and tip guard assem-
bly from gun and place in waste pail.
3.
Lift suction tube and drain tube from
paint pail. Let paint drain into the pail.
4.
Separate drain tube (smaller) from suc-
tion tube (larger).
5.
Place empty waste and flushing fluid
pails side by side.
6.
Place suction tube in flushing fluid. Use
water for water based paint and mineral
spirits or compatible oil-based flushing
solvent for oil-based paint. Place drain
tube in waste pail.
7.
Turn pressure control knob
counter-clockwise to the
Prime/Clean setting.
8.
Turn Prime/Spray valve down to
PRIME position.
9.
Turn ON/OFF switch to ON position.
10.
Flush until approximately 1/3 of the
flushing fluid is emptied from the pail.