FX20 Operator’s Manual Service - 65
25 Hour
CMW
Check Vacuum Tank Door Seals and
Fittings
Check door seal every 10 hours for wear or
damage. Repair if necessary. Check for leaks and
loose fittings every 10 hours. Repair or replace if
necessary.
25 Hour
Vacuum System
Change Water Pump Oil
Change oil after the first 25 hours of operation
and every 100 hours thereafter. Change oil more
frequently if working in dusty conditions.
• Drain at drain plug (2) while oil is warm.
• Refill with NDO at fill (1) until oil is at full mark
on dipstick or at halfway point on sight glass.