PerfectPower Technical data
21
14 Technical data
I
The following technical data applies to all inverters:
NOTE
The constant output in the technical data may be reduced for ambient
temperatures of more than 40 °C (e.g. in engine or heating
compartments or direct sunlight).
PP1002
PP2002
PP1004
PP2004
Output voltage:
230 V
Output frequency: 50 Hz ± 2 Hz
Idle current consumption: < 1.5 A < 1.5 A
Efficiency at constant load: > 85 %
Input voltage range: 11 – 15 Vg 22 – 30 Vg
Mains input voltage: 230 Vw
Low voltage alarm: 11 V 22 V
Low voltage shutdown: 10.5 V 21 V
Low voltage restart: 12.2 V 24.4 V
Excess voltage shutdown: 15.5 V 30.5 V
Overload shutdown: 130 %
Excess temperature shutdown: 80 °C
Priority circuit fuse: 10 A
Ambient temperature
– storage:
– operation:
–30 °C – +70 °C
0°C – +40°C
Humidity
– storage:
– operation:
20 % – 90 %
10 % – 95 %
Testing/certification: