4.3 Clearances
I
The maximum clearances specified are necessary for correct refrigerator performance. CSA International
certification allows the refrigerator to have zero inch minimum clearance at the sides, rear, top, and
bottom.
Clearances
Top (G) 0" Min. to 1/4" Max.
Side (K) 0" Min. to 1/4" Max.
Bottom (L) 0" Min. to 0" Max.
Rear (M
1
) 0" Min. to 1" Max.
1
The distance between the refrigerator cooling unit and the wall or
baffle behind it
7
G
L
K
K
M
4.4 Minimum ventilation heights
Model B1 B2 Model B1 B2
RM2351 31" 28" DM2682 57-3/4" 56"
RM2354 31" 28" DM2683 57-3/4" 56"
RM2451 37-3/4" 36" RM3762 57-3/4" 56"
RM2454 37-3/4" 36" DM2852 63-3/4" 61"
RM2551 44-1/2" 42" DM2862 63-3/4" 61"
RM2554 44-1/2" 42" DM2872 63-3/4" 61"
DM2652 57-3/4" 56" DM2882 63-3/4" 61"
DM2662 57-3/4" 56" RM3962 66-13/16" 63"
DM2663 57-3/4" 56" RM1350 69-1/8" 63"
DM2672 57-3/4" 56" RM1350SL 69-1/8" 63"
B1 = Roof vent and lower side vent / B2 = Upper and lower side vent
Measure the ventilation height from the seam between the frame and the door of the lower side wall vent,
to the top of the roof opening (B1), or to the top of the uppermost row of louvers on the upper side wall vent
(B2).

Other manuals for Dometic RM2354

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dometic RM2354 and is the answer not in the manual?

Dometic RM2354 Specifications

General IconGeneral
BrandDometic
ModelRM2354
CategoryRefrigerator
LanguageEnglish

Related product manuals