46
Remote Operation
7.4.10 *SRE
Syntax
*SRE <enable_value>
Parameters
Enable_value Value that corresponds to the binary-weighted sum of the bits
you wish to enable in the register.
Description
Enable bits in the Status Byte enable register.
To enable bits in the Status Byte enable register, you must write a decimal
value that corresponds to the binary-weighted sum of the bits you wish to
enable in the register.
Note: This command can NOT be concatenated with other commands. It must
be issued as a single command.
7.4.11 *SRE?
Syntax
*SRE?
Description
The *SRE? query returns a decimal value which corresponds to the binary-
weighted sum of all bits enabled by the *SRE command.
Result
Returns a decimal value which corresponds to the binary-weighted sum of all
bits enabled by the *SRE command.
Example
“*SRE?”
Result was “16”
Note: This command can NOT be concatenated with other commands. It must
be issued as a single command.
7.4.12 *WAI
Syntax
*WAI
Description
This command prevents the instrument from executing any further commands
or queries until the current commands have been processed.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Dover Dow-Key Microwave MS-2U18S-4/X-GPIB and is the answer not in the manual?

Dover Dow-Key Microwave MS-2U18S-4/X-GPIB Specifications

General IconGeneral
BrandDover
ModelDow-Key Microwave MS-2U18S-4/X-GPIB
CategorySwitch
LanguageEnglish

Summary

General Information

Technical Specifications

Provides detailed technical specifications for the matrix series, including frequency range, VSWR, and RF power.

Safety Precautions

Highlights essential safety precautions to be observed before using the product and associated instrumentation.

System Layout

Front and Rear Panel Layouts

Illustrates front and rear panel layouts for 2U, 3U, and 4U models, detailing connectors and interface ports.

RF Configuration

Refers to Appendix B for detailed RF configuration information.

Connections

Power and Ground Connections

Details line voltage, power connection steps, fuse replacement, and proper grounding procedures.

Communication Interfaces

Covers RS232, CAN Bus, GPIB, and USB connections, settings, and pinouts.

Configuring the Matrix

Matrix Configuration Basics

Explains the matrix controller's role in managing switch configurations and the importance of configuration data.

Adding and Deleting Switches

Provides rules for adding and deleting switches to/from the matrix configuration.

Manual (LOCAL) Operation

Touch Screen Interface

Details the matrix's touch screen interface for local operation, including power-on and mode switching.

Main Menu Operations

Covers key operations accessed via the Main Menu: Switching, Errors, System Settings, and Communications.

IEEE 488.2 Register Model

Common Commands

Lists and describes common IEEE 488.2 commands like *CLS, *ESE, *ESR?, *IDN?, *OPC, *RST.

Remote Operation

SCPI Introduction and Syntax

Explains SCPI, command syntax rules, separators, keywords, and parameters.

Remote Commands

Details common, system, and switch commands for remote operation via GPIB, RS232, and USB.

Related product manuals