Chapter 8
8.11 Setting the Voice Prompt Volume
This feature is only available when using an HS2LCDWFPV wireless keypad.
To change Voice Prompt volume:
LCD Display
1. From the User Function menu use the shortcut key [1][5] or press the
scroll keys to select Voice Prompt and press [*].
Press (*) for <>
Voice Prompt
2. Enter the 2 digit value or scroll to the desired volume level and press
to return to the previous menu.
Voice Prompt <>
Level... XX
3. Press [#] to return to the Ready state.
8.12 Setting the Voice Chime volume
This feature is only available when using an HS2LCDWFPV wireless keypad.
To change Voice Chime volume:
LCD Display
1. From the User Function menu use the shortcut key [1][6]or press the
scroll keys to select Voice Chime and press [*].
Press (*) for <>
Voice Chime
2. Enter the 2 digit value or scroll to the desired volume level and press
[#] to return to the previous menu.
Voice Chime <>
Level... XX
3. Press [#] to return to the Ready state.
8.13 User's Walk Test
Allows the user to verify the operation of system detectors and notifies the central station that a Walk Test
is in progress and must be configured by installer.
IMPORTANT: During a system (walk) test, do not activate any:
l Fire, Auxiliary or Police buttons
l Fire or CO sensors
A full system test is comprised of activating each sensor in turn. Open each door, window and walk-in
areas with motion detectors. It is recommended you perform system tests during off-peak hours, such as
early morning or late evening.
To initiate a Walk Test:
LCD Display
1. From the ready state press [*][6] and enter the [Master Code] to
access User Functions.
Press (*) for <>
User Functions
2. Press [08] or use the scroll keys to navigate to Walk Test and press
[*]. The system activates all keypad sounders and bell/sirens for two
seconds and also notifies the central Station that a walk test has
begun.
Press (*) for <>
Walk Test
3. Trigger each detector (zone) in sequence. A squawk occurs at the
keypad, all LEDs on the keypad will flash and the violation will be
recorded in the Event Buffer.
4. Restore zones. Press [*][6][Master Code][8] to end the Walk Test.
The system will notify the Central Station that the walk test has been
terminated.
NOTE: Fire zones, the 'F' key, and 2-wire smoke detectors are excluded from this test. Violation of these
zones will cause the system to exit the walk test then generate and transmit an alarm condition to the
central station.
If a zone is not violated within 15 minutes of activating the Walk Test, the system will automatically exit
the Walk Test and resume normal operation.
NOTE: This feature is not available in CP-01 panels.
To Enable/Disable a Walk Test:
LCD Display
1. From the User Function menu, use the shortcut key [08] or press [<]
[>] to scroll to Walk Test.
Press (*) for <>
Walk Test
2. Press [*] to enable/disable the Walk Test feature.
Walk Test
is Enabled
- 31 -