Special functions
Use these functions to perform commands through the
menu or function code system.
Master reset – FC 38
Initial press reset message
Entering FC 38 or accessing this command via the menu
system will cause the LCD to display the following
message:
038 Master Reset
While the Master Reset screen is displayed, pressing
the ESC key causes the LCD to exit the viewing of this
command and to display the previous sub-menu items. Or,
pressing the ENTER key will request a (CONFIRM) before
resetting all demand metering and tap position maximum
and minimum values.
038 Master Reset
(CONFIRM)
Confirm message
While the (CONFIRM) message is displayed: pressing the
ESC key causes the LCD to display the initial Master Reset
screen; pressing the ENTER key causes the execution of
the command. Once the command has been executed, it
will return to the original Master Rest screen.
Enter security code – FC 99
A security code must be entered to enable parameter editing
at the appropriate level. Entering FC 99...
Function Code
_99
...causes the menu system to enter the security code mode:
Security Code
-------
This function code does not have an item in the nested-
menu system and can only be accessed by using the
function code.
Self-test - FC 91
After pressing FUNC, 91 ENTER and accessing the FC 91
display, press ENTER again to select the option and again to
confirm. When the self-test is complete, the LCD displays
the Self-Test Complete screen. Press ESC for further
keypad use.
Test LEDs
Access this under the Diagnostic menu. With the cursor
selecting “Test LEDs” press the ENTER key and the front
panel LEDs will blink three times. The Neutral Light LEDs do
not blink.
Turn display off
Access this from the Main Menu (Level 1). With the cursor
selecting TURN DISPLAY OFF press the ENTER key and the
LCD display will turn off. To turn on the LCD display, press
any button in the keypad.
Alarms
Use the nested menu to access the lists of acknowledged
and unacknowledged system alarms. No security code is
needed to display an alarm; a security code is needed to
acknowledge an alarm.
ALARMS > Alarms Active Unacknowledged
This displays a list of active, unacknowledged system
alarms.
ALARMS > Alarms Active Acknowledged
This displays a list of active, acknowledged system
alarms.
119
INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS MN225003EN April 2018
CL-7 Voltage Regulator Control

Table of Contents

Other manuals for Eaton KA146W5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Eaton KA146W5 and is the answer not in the manual?

Eaton KA146W5 Specifications

General IconGeneral
BrandEaton
ModelKA146W5
CategoryCables and connectors
LanguageEnglish

Related product manuals