APPENDIX F – PARAMETER DESCRIPTIONS
Name Description
5060 Frequency
6Prb Presence of 6-point meat probe (1=yes for lev. A, 0 for lev. B)
AbSP Flag to enable starting of cooking closing the door (0=disable; 1=enable)
Addr RS485 address
ALFn Activation of cavity motor thermal protection
APPL Level of the oven
APPM Type of oven
bAud RS485 bit rate
bot Max. steam generator overheating (ETUB alarm)
CLPr Length of cooling with humidifier after a steam phase in an automatic cleaning cycle
CLt1 Length of detergent injection (phase A)
CLt2 Length of detergent+water injection (phase A)
CLt3 Length of rinser+water injection (phase C)
CLt4 Length of water injection (phase C)
cort Flag to enable cavity temperature displaying adjustment
cot Max. cooking chamber overheating (ETUC alarm)
cu Parameter q of SCELOFF=SCEL-(q+m*dT/dt) (FUZZY-LOGIC)
dbon Delay for boiler drain
dCLn Flag to disable automatic cleaning cycles (1=disable)
dEMO Flag to enable DEMO (0=disable; 1=enable)
Temperature range (from set) above which the middle power is activated in combi
mode
dScb
Flag to disable the oven stops when door is open in convection, steam and combi
mode: (0=the oven stops)
dSod
Flag to disable pre-heating of the boiler when the oven is in stand-by mode (0=enable
pre-heating; 1=disable)
dSPS
Max. cooking chamber temperature derivative value for heating elements to be
switched OFF (FUZZY-LOGIC)
dtoF
Max. cooking chamber temperature derivative value for heating elements to be
switched ON (FUZZY-LOGIC)
dton
dtSb Delay for activation of fast filling during opening of boiler drain valve
dutM Maximum length of a phase with cavity temperature over 250 ºC
EMME Parameter m of SCELOFF=SCEL-(q+m*dT/dt) (FUZZY-LOGIC)
EnFL Presence of motorised cavity flap (1=yes)
Ertc Flag to enable RTC (1=enable)
FAHr Temperature unit (°F = 1, °C = 0)
FrE PWM frequency
Fubo PWM value at full power of boiler burners
FucA PWM value at full power of cavity burners
GAS Define if the oven is GAS heated (1) or ELECTRIC heated (0)
hAbo PWM value at middle power of boiler burners
HAbP Steam condenser engagement in "hot air" mode
hAcA PWM value at middle power of cavity burners
HAFd Bypass temperature variation for humidification during hot air mode + open flap
HAFI By pass isteresys in hot air+open flap mode
HAFS Bypass base temperature for humidification during hot air mode + open flap
hAir Hot air hour counter
File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.30/40

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Electrolux AOS061E Series and is the answer not in the manual?

Electrolux AOS061E Series Specifications

General IconGeneral
BrandElectrolux
ModelAOS061E Series
CategoryOven
LanguageEnglish

Related product manuals