SOI/TD 2004-11 PR 19/26 599 36 44-44
11 USER MODE
With this procedure it is possible to:
• Modify the regeneration level selection (depending on the water hardness).
• Activate or deactivate the rinse-aid supply.
11.1 Regeneration selection
To activate the function:
1. Press and hold down button S1.
2. Turn the knob to Position 1:
The LEDs LD0 and LD1 flash
Release button S1
3. Press button S1
The regeneration level is displayed by the End of cycle
LED which flashes and pauses at intervals: for the
decodification, see summary table of alarms.
Press button S1 to increase the regeneration level
according to the following values:
No. of flashes of
“End of cycle” LED
Water fill between
regeneration
procedures
Time
regeneration
solenoid opens
Position of
tank
selector
Hardness of water
treated
Level
nº Litres sec nº º F (TH) º D (dH)
1
1 - - - 0 1 0 > 7 0 > 4
2
2 130 240 1 8 > 18 4 > 10
3
3 94 240 1 19 > 25 11 > 14
4
4 70 240 1 26 > 32 15 > 18
* 5
5 53 240 2 33 > 39 19 > 22
6
6 37 240 2 40 > 50 23 > 28
7
7 20 240 2 51 > 64 29 > 36
8
8 15 240 2 65 > 75 37 > 42
9
9 10 240 2 76 > 90 43 > 50
10
10 3 2x240 2 91 > 125 51 > 70
* “5” = Level set by factory Position of tank selector: “2”