SOI/TD 2004-11 PR 26 599 36 44-44
6/
4 CONTROL PANEL
The configuration of the control panel depends on the following:
styling
number of buttons from a minimum of 1 (only Start/Reset) to a maximum of 2
number of LEDs
[S1
] - Start button
[S2
] - OPTION SELECTION button
[LD0
- On/Off LED
[LD1
]- Start LED
[LD2
]- LED “OPTION” activated
[LD3
] … [LD5] - LEDs “CYCLE PHASES”
[LD6
] [LD7] - LEDs “SALT / RINSE-AID”
4.1 Start/Reset (S1) button
All models feature this button and it is used to start or interrupt a washing cycle; if it is activated during
a cycle it does not cause the cancellation of the current programme. It is used to enter the diagnostics
mode.
4.2 Option (S2) button
The system used for selecting the wash programmes depends on the configuration of the model:
- Delayed start
- Half load
The functions of the various buttons and LEDs depend exclusively on the software
configuration of each appliance; for detailed information please refer to the programme table of the
specific model.
5 WASHING PROGRAMMES
The number and types of wash programmes and options vary with the configuration of the model (max. 5):
Type
Programme
Prewash (ºC)
Wash (ºC)
No. of rinses
Option
½ load
Min. ~
I2
Intensive
55 68 3
⊗
120’
N5
Normal 3 rinses
Cold
68 3
⊗
102’
E1
Energy label xxx
Cold
62 max 2
⊗
162’
Q4
Soak
Cold -- -- --
12’
Q5
Short 30 min
--
65 max 1 --
31’
NB: If during the programme, the knob is turned to any position, but not the “0”, it continues without
any modification.