DOC. NO. 5956.65J.00 P. 11 / 174
EFS - Dishwashing Systems Platform
Electrolux Professional
6 TEMPERATURE SETTING
In this paragraph is explained how to change temperature thresholds and all parameters related to boiler and
tank
.
6.1 Factory Parameters
Sym. Parameter Description Unit Min Max
Factory
Default
Boiler Temperature: THRESHOLD.
When boiler temperature reaches this value, heaters switch off.
[°C] 45 95 78
Boiler Temperature HISTERESIS, (represent dead band).
Heater switch on if boiler temperature is below:
-
[°C] 2 10 2
Boiler Temperature: HIGH LIMIT.
When boiler temperature reaches this value
alarm appears.
Put 0 to disable
alarm.
[°C] 0 98 96
Boiler Temperature: LOW LIMIT.
During boiler warm-up, temperature must increase at least
°C
otherwise
warning appears.
Put 0 to disable
warning.
[°C] 0 10 1
Boiler Filling Timeout.
If filling time is longer than
, alarm appears.
Put 0 to disable
alarm.
[min] 0 42 5
Boiler Temperature Adjust.
[°C] 0 7 4
Boiler Priority (enable boiler wait function)
0=disabled
1=enabled
-01 1
Booster Function
Overheat gap over Boiler Temperature Threshold
[°C] 0 15 2
Boiler temperature negative differential: when the dishwasher is in
standby, boiler threshold becomes:
-
(Used to save energy during machine inactivity by keeping boiler
water at a lower temperature).
[°C] 0 20 0
Tub Temperature: THRESHOLD
When tank temperature reaches this value, heater switch off.
[°C] 40 85 63
Tub Temperature: HISTERESIS, (represent dead band).
Heater switch on if tank temperature is below:
-
[°C] 2 30 5
Tank Temperature: HIGH LIMIT.
When tank temperature reaches this value
alarm appears.
Put 0 to disable
alarm.
[°C] 0 95 75
Tank Temperature: LOW LIMIT.
During tank warm-up, temperature must increase at least °C
otherwise
warning appears.
Put 0 to disable
warning.
[°C] 0 10 1
Tank Filling Timeout.
If filling time is longer than , alarm appears.
Put 0 to disable
alarm.
[min] 0 42 20