DOC. NO. 5956.65J.00 P. 17 / 174
EFS - Dishwashing Systems Platform
Electrolux Professional
8.2 Read Only Parameters
8.3 Communication and HACCP Parameters
Sym. Parameter Description Unit Min Max
Factory
Default
Main Board Firmware Release
--- -
Water softener board software version. (only for dishwashers with
incorporated continuous water softener).
--- -
Active column: indicates through which of the two continuous
water softener columns boiler filling is being carried out: 0 = col-
umn A and 1 = column B (only for dishwashers with incorporated
continuous water softener).
--- -
When
message appears, the parameter value becomes 3.
After maintenance, to clear message, insert 0.
--- -
When alarm appears, the machine is frozen and this
parameter is 3.
After maintenance (see alarm codes document), insert 0 to ena-
ble the machine.
--- -
This alarm appears in case of malfunctioning in the continuous
water softener. To facilitate fault-finding, see par. 13.3 ALARMS
THAT DON’T STOP THE DISHWASHER FOR MODELS WITH
INCORPORATED CONTINUOUS WATER SOFTENER.
--- -
Sym. Parameter Description Unit Min Max
Factory
Default
Serial Device
0 = 8N1
1 = PC connection (DAAS 8E1)
7 = HACCP network (ECAP 8E1+LK485) (LK485 board is nec-
essary)
9 = Dishwashers with incorporated continuous water softener
16 = HACCP printer (8N1)
32 = MODEM GSM (DAAS 8N1)
33 = MODEM GSM (DAAS 8E1)
48 = Hyper Terminal (8N1)
-063
1
Address.
This parameter specifies the address of the appliance into the
‘HACCP_network’.
Works only if ‘HACCP network’ is selected (see above parameter).
- 0 255
1
Print parameter table.
-01
1
HACCP ‘Basic’ (printer)
Boiler temperature: high limit.
[°C] 45 95
90
HACCP ‘Basic’ (printer)
Boiler temperature: gap below high limit.
[°C] 0 20
10
HACCP ‘Basic’ (printer)
Tank temperature: high limit.
[°C] 35 75
68
HACCP ‘Basic’ (printer)
Tank temperature: gap below high limit.
[°C] 0 20
10