Table 2-2: Configuration Values
(continued)
Configuration option Default value
X_YFMAX 1000 Hz
Z LOR 1600 lines
Z FMIN 1000 Hz
Z FMAX 1000 Hz
Z Peakvue LOR Z velocity spectrum
Z Peakvue HP Filter 2
Z Peakvue FMAX 65
Velocity Band 1 Source Z velocity spectrum
Velocity Band 1 Start 2
Velocity Band 1 Stop 65
Velocity Band 2 Source Z velocity spectrum
Velocity Band 2 Start 65
Velocity Band 2 Stop 300
Acceleration Band 1 Source Z acceleration spectrum
Acceleration Band 1 Start 10
Acceleration Band 1 Stop 500
Acceleration Band 2 Source Z acceleration spectrum
Acceleration Band 2 Start 500
Acceleration Band 2 Stop 1000
2.6.3 Publish mode
The device publishes all device variables and status in three bursts. In cases where a third
party host or other control system configures the burst configuration in a custom mode,
the DD allows the user to reset the burst configuration to the default burst mode.
However, it is strongly recommended that the device bursting not be manipulated as it
has been optimized to provide all device variables and status bytes, hence allowing any
potential data from the device to be cached in the gateway, minimizing opportunity for
errant communication from a 3rd party host or other control system to wake the device
due to burst misconfiguration.
2.6.4
Update rate
The default update rate is 60 minutes. This is the maximum (fastest) recommended
update rate. You can change this at commissioning or at any time through AMS Device
Manager, the AMS Trex Communicator, or the Smart Wireless gateway web server.
The update rate can be set from 1 minute to 60 minutes (with 1-second resolution) and
from 1 hour to 24 hours (with 1-hour resolution, always rounding to the next hour).
User Guide
Configuration
MHM-97927-PBF August 2020
MHM-97927-PBF, Rev 1 39