Table A-5: Z Overall
(continued)
Axis Severity Upper Limit Lower Limit Units Notes
Z Overall Sensor 70 0 in/s Read-only
Z Overall Range 5 0 in/s Can be set by
the user up to
the sensor
range
Z Overall Fail 1 0 in/s
Z Overall Maint 0.35 0 in/s
Z Overall Advise 0.14 0 in/s
Table A-6: Z Peakvue
Axis Severity Upper Limit Lower Limit Units Notes
Z Peakvue Error Not Applicable Not Applicable 250 Read-only
Z Peakvue Unused Not Applicable Not Applicable 250 Read-only
Z Peakvue Saturated 100 0 g Can be set by
the user up to
the sensor
range
Z Peakvue Sensor 100 0 g
Z Peakvue Range 100 0 g
Z Peakvue Fail 40 0 g
Z Peakvue Maint 20 0 g
Z Peakvue Advise 10 0 g
Table A-7: IB1 Velocity
Axis Severity Upper Limit Lower Limit Units Notes
IB1 Velocity Unused Not Applicable Not Applicable 250 Read-only
IB1 Velocity Saturated 70 0 in/s Read-only
IB1 Velocity Sensor 70 0 in/s Can be set by
the user up to
the sensor
range
IB1 Velocity Range 5 0 in/s
IB1 Velocity Fail 0.6 0 in/s
IB1 Velocity Maint 0.21 0 in/s
IB1 Velocity Advise 0.084 0 in/s
Specifications and reference data User Guide
August 2020 MHM-97927-PBF
68 MHM-97927-PBF, Rev 1