EasyManuals Logo
Home>Emerson>Controller>FXMP25

Emerson FXMP25 User Manual

Emerson FXMP25
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
FXMP25 User Guide 29
Issue Number: 3 www.controltechniques.com
Safety information
Product
information
Mechanical
installation
Electrical
installation
Getting started
Parameters Setting-up Technical data Diagnostics UL listing information
5.4 Setting the controller back to default values
If Pr 00 is set to a non-zero value and edit mode is exited, the field controller is reset
when the field controller is inactive (Pr 77= OFF), the selected default parameters will
automatically be loaded. After the parameters have been set to default values, they are
automatically saved to the field controller’s EEPROM on power down. New values will
take effect on subsequent power up.
Table 5-1 Pr 00 settings
Table 5-2 Status modes
To set defaults from MP or MII Mode, set Pr 78 = OFF then press to exit edit mode.
A power cycle is then required to gain access to Pr 00.
5.5 Saving parameters
Parameters are automatically saved when the MODE key is pressed when going
from parameter edit mode to parameter view mode.
Value Display Function
0 nonE No action
1 Eur Load European defaults
2 USA Load USA defaults
If loading default when the drive is active, the display will flash FAIL once and then
Pr 00 will be change back to nonE.
NOTE
Left hand
display
Status Explanation
Field controller
inhibited
The field controller is inhibited because the field controller
is disabled (Pr 77 = OFF).
Field controller has
tripped
The field controller has tripped. The trip code will be
displayed in the ‘right hand’ display
(see Chapter 9 Diagnostics on page 60).
Field controller is
running
The field controller is in a run state.
Pr 78 = Mode Selected an
Pr 77=On Standalone Mode or
Mentor MP Pr 5.77=On in MP Mode or
Mentor II ribbon cable is connected in Mentor II mode.
M
M
A parameter change is not saved if a drive trip occurs when the parameter is changed.
NOTE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson FXMP25 and is the answer not in the manual?

Emerson FXMP25 Specifications

General IconGeneral
BrandEmerson
ModelFXMP25
CategoryController
LanguageEnglish

Related product manuals