30 FXMP25 User Guide
www.controltechniques.com Issue Number: 3
6 Parameters
All parameters are available in default Pr 78 = OFF (0)
In the table below the abreviations used in the table have the following meaning:
MP - In Mentor MP mode the field controller is being controlled by Mentor MP.
MII - In Mentor II mode the field controller is being controlled by Mentor II.
ST - In Stand alone mode the field controller is controlled by itself.
Table 6-1 Quick look-up parameter table
Parameter numbers are numbered so they match Mentor MP menu 5 parameters.
For example Pr 77 FXMP=Pr 5.77 on Mentor MP
Pr Description MP MII ST Pr Description MP MII ST
00 Loading defaults
9
67 Field economy level 9
01 FXMP25 OK
9
9
9
68 Maximum flux / voltage limit 9
02 Armature voltage
9
69 Minimum flux / voltage limit 9
03 Flux reference
9
70 Rated field current 9
04 Flux reference input offset
9
71 Flux loop P gain 9
05 Flux reference scaling
9
72 Flux loop I gain 9
06
Armature voltage output scaling
9
73 Rated field voltage 9
07 Field flux output scaling
9
9
9
74
Rated field compensation
factor
9
11
Field current feedback scaling
9 75 Field voltage mode select 9
12 Autotune
9
76 AC supply 99
25 FXMP25 OK flux level 9
9
77 Enable field control 9
26 FXMP25 OK hysteresis level 9
9
78 Field mode 999
27 Flux threshold level exceeded 9
9
80 Economy level selected 9
29 Motor saturation breakpoint 1
9
81 Digital input control
9
30 Motor saturation breakpoint 2
9
90 Trip 0 999
54 Flux feedback
9
9
9
91 Trip 1 999
55 Flux / voltage demand
9
92 Trip 2 999
56 Field current feedback
9
9
9
93 Trip 3 999
57 Percentage voltage demand
9
94
Parameter displayed at power
up
9
58 Field firing angle
9
95 Serial address 9
59
Field weakening voltage set
point
9
96 Baud rate 9
60 Field output voltage
9
97 Software version 999
62 Field weakening loop P gain
9
98 User security code 999
63 Field weakening loop I gain
9
99 Power software version 999
64 External flux reference select
9

Questions and Answers: