If field weakening is required:
From European defaults:
•Set Pr 59 (Field weakening voltage set point)
•Set Pr 69 (minimum flux / voltage limit)
From USA defaults:
•Set Pr 59 (Field weakening voltage set point)
•Set Pr 69 (minimum flux / voltage limit)
•Set Pr 70 ( F ie l d r a t e d c ur r e n t)
Enable the field
controller
To enable the field controller:
•Set Pr 77 (Enable field control) = On (1)
Close field
economy jumper
Close field economy input (Ion) so that Pr 80 (Economy level
select) is OFF (0).