Ignition sequence
The spark plug is being
preheated.
The endless screw
loads the pellets, the
spark plug is heating
The stove is in the
stabilization phase,
the spark plug turns
o and the endless
screw loads the pellets
if necessary.
The stove is running,
the number indicates
the power.
The stove has reached
the set temperature
and switches 1
to maintain this
temperature.
The stove has reached
the set temperature
and is starting the
shutdown sequence.
Shutdown sequence
The stove is in the
cooling phase, the
smoke extractor is at
maximum speed.
The stove is in the
brazier cleaning
phase, the smoke
extractor is at
maximum speed.
Is displayed in the
event of an ignition
attempt during a
cooling cycle. Wait
for the end of cooling,
clean the brazier, and
light again.
The stove is turned o
USE
Press for at least 2 seconds to turn on or turn o the stove
The behavior of the stove depends on the selected mode (see installation manual):
Event Behavior in Eco mode Behavior in Eco Stop mode
Manual ignition
or start of a programmed period
Initiation of the ignition sequence
Initiation of the ignition sequence
The room temperature exceeds
the set temperature.
The stove gradually lowers to power 1 The stove gradually lowers to power 1 then stop
The room temperature drops below
the set temperature.
The power increases up to the set value
Initiation of the ignition sequence
to reach the set power
Manual stop
or end of a programmed period
Initiation of shutdown sequence
(cool down then shutdown)
Initiation of shutdown sequence
(cool down then shutdown)
The display indicates the dierent operating phases :
Power adjustment
• Press , the screen displays "pot"
• Adjust the desired power using the
buttons
and
• Press to get out of the
adjustment cycle
• After a minute without actions, the
output is automatic
Silent mode is activated when the stove is at power "1".
The room air fan turns o.
Set temperature adjustment
• Press , the screen displays "set"
• Adjust the desired temperature using
the buttons
and
• Press
to get out of the
adjustment cycle
• After a minute without actions, the