CLEANING
Before carrying out any maintenance on the stove, take the following precautions:
Ensure that all parts of the stove are cold;
Ensure that the ashes are completely extinguished;
Make sure the main switch is in position "0";
Disconnect the plug, thus avoiding any accidental contact;
Daily cleaning
Turn the stove o by placing
the switch on "0"
Open the door and suck up
the accumulated ashes.
Take the brazier out of the stove. Take out the ashtray.
Vacuum all the ashes in the brazier and the
ashtray. Make sure that all holes in the brazier let
the air pass.
Vaccum the brazier support and all the
accessible parts
Put back the ashtray and the
brazier.
1 432
65 7
ALARM MESSAGES :
NO ACC
Is displayed in the event of an ignition error.
In this case, the stove goes into controlled
cooling. Erase the message by pressing for
more than 2 seconds.
NO FIRE
Is displayed in the event of unwanted
extinction of the stove. In this case, the stove
goes into controlled cooling.
Erase the message by pressing
for more
than 2 seconds.
SERV
Is displayed when the stove has reached 1,200
hours of operation.
In this case, please contact the approved
service center for seasonal maintenance.
BLACK OUT
Is displayed if the power supply was cut
during the operation of the stove. In this case,
the stove goes into controlled cooling. Erase
the message by pressing
for more than 2
seconds.
DEP SIC FAIL
Is displayed in the event of an anomaly
detected by the pressure probe or the
thermostat. In this case, the stove goes into
controlled cooling.
Erase the message by pressing
for more
than 2 seconds.
Have the thermostat safety devices checked
by an approved service center.
FAN FAIL
Is displayed in the event of a smoke extraction
fan failure. In this case, the stove goes into
controlled cooling.
Erase the message by pressing
for more
than 2 seconds.
HOT PCB
Is displayed if, during operation, the electronic
card reaches and exceeds 70 ° C for more
than 3 minutes. In this case, the stove goes
into controlled cooling. Erase the message by
pressing
for more than 2 seconds.
Have the stove checked by an approved
service center.