FEASA LED ANALYSER
FUNCTIONAL VERSION
Daisy Chain Mode
BusC - Initiate Capture for all LED Analyser's
Transmit Receive
busc OK
Description
This command will cause all LED Analysers in the Daisy Chain to initiate a capture sequence
using the Automatic Range Mode. To specify a Range manually see the command BusC# on
the next page.
After the capture cycle use the command BusGet#### to activate a specific LED Analyser.
All the standard commands can then be used to read back the LED Test data.
Example:
The PC transmits busc to instruct all LED Analysers in the Daisy Chain to initiate a Capture
cycle.
busc
OK