Permitted cables AC cables with the following design can be connected to the AC terminals of the inverter:
- Copper (Cu) or aluminum (Al): round, solid
- Copper: round, stranded, up to conductor class 4
Cu / Al Cu
AC & DC = copper cables (Cu)
The following wire combinations can be used for wiring.
Select a sufficiently large cable cross-section based on the actual device output!
AWG
round
AWG
strand
ed
AWG
stranded/round
AWG
round/round
AWG
stranded/stranded
4
2)
6
2)
6/6
4)
6/12
2)
6/14
2)
6/16
3)
8
2)
8
1)
8/10
1)
8/12
1)
8/14
1)
8/12
2)
8/10
2)
8/12
1)
8/14
1)
8/16
3)
10
2)
10
1)
10/10
1)
10/12
1)
10/14
1)
10/10
1)
10/12
1)
10/14
1)
10/16
3)
12
2)
12
1)
12/10
1)
12/12
1)
12/14
1)
12/16
1)
12/10
1)
12/12
1)
12/14
1)
12/16
1)
14
2)
14
1)
14/10
1)
14/12
1)
14/14
1)
14/16
1)
14/10
1)
14/12
1)
14/14
1)
14/16
1)
16
3)
16
3)
16/14
1)
16/16
1)
16/10
3)
16/12
1)
16/14
1)
16/16
1)
AC & DC = aluminum cables (Al)
The following wire combinations can be used for wiring.
Select a sufficiently large cable cross-section based on the actual device output!
AWG
round
AWG
strand
ed
AWG
stranded/round
AWG
round/round
AWG
stranded/stranded
4
2)
6
2)
6
4)
6/12
2)
6/14
2)
6/16
5)
8
2)
8
2)
8/10
2)
8/12
2)
8/14
2)
8/12
2)
8/10
2)
8/12
2)
8/14
2)
8/16
5)
10
2)
10
2)
10/10
2)
10/12
2)
10/14
2)
10/10
2)
10/12
2)
10/14
2)
10/16
5)
12
2)
12
2)
12/10
2)
12/12
2)
12/14
2)
12/10
2)
12/12
2)
12/14
2)
12/16
2)
14
2)
14
2)
14/10
2)
14/12
2)
14/14
2)
14/16
2)
14/10
2)
14/12
2)
14/14
2)
14/16
2)
16
5)
16
5)
16/14
2)
16/16
2)
16/10
5)
16/12
2)
16/14
2)
16/16
2)
1)
tested and inspected as per UL
2)
not inspected as per UL; connection possible
3)
with ferrules only
4)
use stranded PV (ZKLA) or 2-wire
5)
not inspected as per UL; connection possible; AWG 16 with ferrules only
AC~ Minimum AWG in acc. to NEC
10.0-3 208–240 12.0-3 208–240
Copper (Cu)/aluminum (Al)
208 V
AC
AWG 10/AWG 10 AWG 10/AWG 8
220 V
AC
AWG 10/AWG 10 AWG 10/AWG 8
240 V
AC
AWG 12/AWG 10 AWG 10/AWG 10

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Symo Advanced Series and is the answer not in the manual?

Fronius Symo Advanced Series Specifications

General IconGeneral
BrandFronius
ModelSymo Advanced Series
CategoryInverter
LanguageEnglish

Related product manuals