EasyManuals Logo
Home>Fujitsu>Air Conditioner>ABYG36KRTA

Fujitsu ABYG36KRTA User Manual

Fujitsu ABYG36KRTA
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #67 background imageLoading...
Page #67 background image
2-22. E: 74. Outdoor temperature thermistor error (Outdoor unit)
Indicator
Wired remote
controller
Error code E: 74
Detective actuator
Outdoor unit main PCB When outdoor temperature thermistor open or short
circuit is detected at power on or while running the
compressor
Outdoor temperature thermistor
Forecast of cause
Connector failure
Thermistor failure
Main PCB failure
Check point 1. Check connection of connector
Check if connector is loose or removed.
Check erroneous connection.
Check if thermistor cable is open
-> Reset power when reinstalling due to removed connector or incorrect wiring.
Check point 2. Remove connector and check thermistor resistance value
For the outdoor temperature thermistor resistance value, refer to "Thermistor re-
sistance values" on page 03-58.
If thermistor is either open or shorted, replace it and reset the power.
Check point 3. Check voltage of main PCB
Make sure circuit diagram of outdoor unit and check terminal voltage at thermistor
(DC 5.0 V).
NOTE: For details of thermistor connector, refer to "Wiring diagrams" in Chapter 2.
TECHNICAL DATA AND PARTS LIST on page 02-17.
If the voltage does not appear, replace main PCB.
End
2-22. E: 74. Outdoor temperature thermistor error (Outdoor unit) - (03-27) - 2. Troubleshooting with error code
TROUBLESHOOTING
TROUBLESHOOTING

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ABYG36KRTA and is the answer not in the manual?

Fujitsu ABYG36KRTA Specifications

General IconGeneral
StyleSplit-type
ColorWhite
FeaturesBladeless Design
Min/Max: 0.50-3.20 kW000 BTU/h
Min/Max Cooling 2.20/8.00 kW?860-11
29.5 (2.8 - 11.2) kW
Min/Max: 0.50-4.40 kW000 BTU/h
Min/Max Heating 1.90/9.00 kW?000 Btu/h
Moisture Removal2.60 l/h
Fan Airflow RateHigh / Mid / Low: [CMM] (C) 17.5/15.9/14.3 (H) 17.5/15.9/14.3 CMM
Heating (?): 10.0 ~ 45.0 ?Cooling: -15 to 46 °C DB
Sound Pressure LevelIndoor (Cooling) : High 44 dB(A)
Indoor (Heating): High 44 dB(A)36 / 26 / 23 dBA (H / L / QLo)
Refrigerant TypeR32
Refrigerant Charge-
Annual Energy ConsumptionCooling: 524 kWh/a
Heating: 2904 kWh/a-
Heating: 4.12 WCooling: 2.910 kW
Frequency50 Hz
Voltage230 V
Heating: 6.60 AMax Cooling: 22.60 A
Battery Life-
Battery Capacity-
Depth705 mm
Height235 mm
Width1700 mm
Net Weight38.0 kg