EasyManuals Logo
Home>Fujitsu>Air Conditioner>ASYG14LTCB

Fujitsu ASYG14LTCB User Manual

Fujitsu ASYG14LTCB
53 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #52 background imageLoading...
Page #52 background image
-
(
02 - 16
)
-
OUTDOOR UNIT
AO
G09-14LT
OUTDOOR UNIT
AO
G09-14LT
ELECTRIC CHARACTERISTICS9.
Model name AO
G09LT AO
G12LT AO
G14LT
Power supply
Voltage V 230 ~
Frequency Hz 50
*1) Max operating current A 10.0 11.5 14.5
Starting Current A 3.3 4.3 6.1
*2) Wiring Spec.:
Main Fuse (Circuit breaker)
Current
A15 20
Power Cable mm
2
1.5 3.5-4.0
*3) Limited wiring length : m 15 13 24
*1) The maximum current is the total current of indoor unit and outdoor unit.
*2) Wiring Spec.:
Selected Sample
(Selected based on Japan Electrotechnical Standard and Codes Committee E0005)
*3) Limited wiring length :
This is the wiring length in case voltage descent is less than 2%.
When the wiring length becomes long, please select the wiring of a more larger diameter.

Other manuals for Fujitsu ASYG14LTCB

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASYG14LTCB and is the answer not in the manual?

Fujitsu ASYG14LTCB Specifications

General IconGeneral
BrandFujitsu
ModelASYG14LTCB
CategoryAir Conditioner
LanguageEnglish

Related product manuals