02 - 17
)
-
OUTDOOR UNIT
AO
G09-14LT
OUTDOOR UNIT
AO
G09-14LT
SAFETY DEVICES10.
Protection form
Model
AO
G09LT
AO
G12LT
AO
G14LT
Circuit protection
Current fuse
(NEAR THE TERMINAL)
20A 250V
Current fuse
(MAIN PRINTED CIRCUIT
BOARD)
20A 250V 10A 250V
5A 250V 3.15A 250V
Fan motor protection
Thermal protection
program
OFF : 150°C
ON : 120°C
OFF : 100±10°C
ON : 95±10°C
Compressor protection
Thermal protection
program
(DISCHARGE TEMP.)
OFF : 110°C
ON : After 7 minutes