6. SYSTEM DESIGN
WIRED REMOTE CONTROLLER5-8.
MODEL: UTY-RVN5-8-1.
îš¾
M
DIP
Switch
SW1
Memory backup setting
SW2
Dual remote controller setting
SWITCH POSITION

Wired remote controller

DIP SWITCH SETTING

Memory backup setting

Set to ON to use batteries for the memory backup.
If batteries are not used, all of settings stored in memory will be deleted if there is a power
failure.
(
u
...Factory setting)
SW1 Memory backup
u
OFF Disable
ON Enable
Dual remote controller setting

Set the remote controller SW2 according to the following table.
(
u
...Factory setting)
Number
of remote
controller
Primary unit
Secondary
unit
SW2 SW2
u
1 (Normal) OFF -
2 (Dual) OFF ON
1 231 23
1 2 3
Indoor unit
Remote controller cable
Primary unit
Secondary
unit
Remote controller