Check List
5
5.3 Loop back test
Start Loop back test which the message is send back to the own ship. The transmitting and
receiving message should be printed out.
1) Make a test message by “New” ([F1]-1).
2) Set following items by “Transmit Message” ([F3]-1).
- Priority : Normal
- Destination Type : TELEX
- Country/Ocean Code : The Ocean region to be selected
POR: 582, IOR: 583, AOR-W: 584, AOR-E: 581
- Station ID : To enter the own IMN
- LES ID : LES
- Option
Confirmation : ON
Send Delay : 00:00
Delivery Dela : Immediate
Code : IA5
3) Move the cursor onto “Transmit” and press [Enter].
4)
Select “YES” and press [Enter] to start the transmission.
5) When the same message is received after 5 to10 minutes, the test result is OK. If the
message cannot received correctly, confirm “Delivery” in “Send Message Log”
([F6]-1). See page 7.
5.4 EGC receiving
The alarm is checked by following the message priority.
The alarm is sounded from IC-305 and the Terminal unit by DIS/URG Message.
See page 2-17. The EGC receiving message should be printed out. See page 4-6.

Table of Contents

Other manuals for Furuno FELCOM 15

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno FELCOM 15 and is the answer not in the manual?

Furuno FELCOM 15 Specifications

General IconGeneral
BrandFuruno
ModelFELCOM 15
CategoryMarine Radar
LanguageEnglish

Related product manuals