3. INITIAL SETTINGS
3-4
5. Confirm that the [IMN] is selected, and then press the Enter key.
An input box appears.
6. Key in your IMN.
7. Press the Enter key.
8. Press the Esc key to erase the input box.
9. Press the Enter key.
To clear the IMN, select IMN, then press I, M, N while pressing the Alt key. When us-
ing the FELCOM19 for VMS (Vessel Monitoring System), DNID (Data Network ID) has
to be downloaded via the LES (Land Earth Station). This arrangement is normally
done by authority of VMS.
3.3 How to Select Position-fixing Equipment
Select the position-fixing equipment that is to feed navigation data to the FELCOM.
1. Press the F8 and 1 keys to show the [System Setup] menu.
2. Select [Nav Port] then press the Enter key.
3. Select the navigator connected to the FELCOM then press the Enter key.
OFF: No navigator connected.
Auto: If two or more navigators are connected, the FELCOM automatically se-
lects the position sensor in the order of GPS and Loran C.
INT: Use the navigator that is built into the communication unit.
EXT: Use an external navigator.
4. Press the Esc key several times to close the menu.

Other manuals for Furuno FELCOM 19

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno FELCOM 19 and is the answer not in the manual?

Furuno FELCOM 19 Specifications

General IconGeneral
BrandFuruno
ModelFELCOM 19
CategorySecurity System
LanguageEnglish

Related product manuals