NX-148E LCD Code Pad Installation and Setup Manual
12
Possible Log Messages
Display Description
Txlobat Transmitter Low Battery - The transmitter has a low battery.
ZN Lost Zone Lost - A wireless or multiplexed zone device is not reporting to the control.
Duress Duress - The control has been armed or disarmed with a duress code.
Man Fire Manual Fire - Code pad ‘Fire’ has been activated.
Aux 2 Auxiliary 2 - Code pad ‘Medical’ has been activated.
Panic Panic - Code pad ‘Panic’ has been activated.
KP Tamper Code pad Tamper - The code pad tamper has been activated.
BoxTamp Box Tamper - The box tamper circuit has been activated.
AC Fail AC Fail - AC failure has been detected.
OverCur Over Current - A short circuit of a power supply has occurred.
Srn Tamp Siren Tamper - A siren or speaker tamper has been detected.
Tel Flt Telephone Fault - A telephone fault or tamper has been detected.
Exp Trb
Expansion Trouble - An expansion device or code pad is not reporting to the
control panel.
Log Full Log Full - The event log is full.
Open Open - Reports user number, date, time and area of opening.
Close Close - Reports user number, date, time and area of closing.
Exit Err Exit Error - Entry/Exit zone was faulted at the instant the exit delay expired.
Rec Close Recent Close - An alarm occurred within 5 minutes after the control was armed.
Autotest Auto Test - Sending a communicator test at a specified interval.
Start Prog Start Programming - Local programming is started.
End Prog End Programming - Local programming is ended.
Start Dnld Start Download - Download session is started.
End Dnld End Download - Download session is ended.
Cancel Cancel - System is disarmed; Cancel was initiated within 5 minutes of an alarm.
Gnd Flt Reserved.
Man Test Manual Test - Bell and/or communicator test while system is in disarmed condition.
Re-exit Re-Exit - The exit delay has been re-started without disarming the system.
Output Trip Output Trip - A trip has occurred on an expander auxiliary output.
Data Lost Data Lost - Communication of a signal has failed (log only event).
Walk-test Walk-Test - A zone ‘Walk-Test’ mode has been activated.
End Test End Test - Test has been ended.
Cross-Trip Cross Trip - The first zone of a cross zone has been tripped (log only event).
Expansion Event
Expansion Event - An expansion module has created an undefined event.
Partial Arm Partial Arm - Reports a closing in the stay mode.
Listen In Listen In - A listen in function has been activated.
Service Start Service Start - Technician is on site.
Service End Service End - Technician is off site.
Code Entry Code Entry - A code has been entered.
First Open First Open - Reports when the first area is disarmed.
Last Close Last Close - Reports when the last area is armed.
Sprnklr Sprinkler - Instant sprinkler supervisory report
Clock Set Clock Set - Clock has been reset.
RF Jammed RF Jammed - A wireless expansion module is jammed by another RF device
CleanMe Clean Me - A smoke detector requires cleaning.

Other manuals for GE NetworX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX Series and is the answer not in the manual?

GE NetworX Series Specifications

General IconGeneral
BrandGE
ModelNetworX Series
CategoryControl Unit
LanguageEnglish

Related product manuals