64
880397M_MSW_GFX4-GFXTERMO4_08-2018_ENG
CT AUXILIARY INPUT
405
x.tA1
R/W
Maximum scale limit of current trans-
former CT input (phase 1)
413
x.tA2
R/W
Maximum scale limit of current trans-
former CT input (phase 2)
414
x.tA3
R/W
Maximum scale limit of current trans-
former CT input (phase 3)
220
o.tA1
R/W
Offset correction for current transformer
CT input (phase 1)
415
o.tA2
R/W
Offset correction for current transformer
CT input (phase 2)
416
o.tA3
R/W
Offset correction for current transformer
CT input (phase 3)
219
661
dG.t
R/W
Sampling interval for CT input
FT.TA
R/W
Digital filter for CT input
(phases 1, 2 and 3)
VOLTAGE VALUE ON LOAD (Voltmeter)
410
x.tU1
R/W
Maximum scale limit of voltage trans-
former VT input (phase 1)
227
473 - 139
I.ta1
R
Instantaneous value of CT input
(phase 1)
490
I.ta2
R
Instantaneous value of CT input
(phase 2)
491
I.ta3
R
Instantaneous value of CT input
(phase 3)
417
x.tU2
R/W
Maximum scale limit of voltage trans-
former VT input (phase 2)
418
x.tU3
R/W
Maximum scale limit of voltage trans-
former VT input (phase 3)
411
o.tU1
R/W
Offset correction of TV input (phase 1)
419
o.tU2
R/W
Offset correction of TV input (phase 2)
420
o.tU3
R/W
Offset correction of TV input (phase 3)
412
FT.TU
R/W
Digital filter for TV auxiliary input
(phase 1, 2, 3)
468
I.1oN
R
Value of CT input with active output
(phase 1)
498
I.2oN
R
Value of CT input with active output
(phase 2)
499
I.3oN
R
Value of CT input with active output
(phase 3)
492
1.tU2
R
Value of voltmeter input (phase 2)
493
1.tU3
R
Value of voltmeter input (phase 3)
232
485
1.tU1
R
Value of voltmeter input (phase 1)