,167$//$7,21
*$6&211(&7,216
- The gas supply diameter is 1".
- With natural gas, a gas stop valve in conformity
with Gas Regulation has to be installed on the
boiler gas supply pipe in an easily accessible lo-
cation. With propane, the 37 mbar release mech-
anism that acts as a gas cock must also be
accessible. Use only
sealings approved for gas.
- On high pressure mechanical testing of the gas
piping, the boiler should not be connected
(Pmax: 100 mbar).
- Always blow through gas piping before commis-
sioning the boiler (to evacuate particles created
by soldering or from threaded joints).
- After commissioning the installation, check that
the pressure test points are properly closed and
check the general leaktightness of the gas circuit
(e.g. using a foaming agent or a U-tube manom-
eter).
- The gas supply pipe to the boiler should never
cause a pressure drop of more than 1 mbar
(10 mmWG).
Example: natural gas type H G20 20 mbar for
10 metres of pipe with 4 elbows (1 elbow roughly
equivalent to 0.5 metre) minimum diameter 26/28.
(/(&75,&$/&211(&7,216
Protection index IP 44 (sealed model - C
33
) - IP 24
(model B
23
).
Power supply cable 3 x 1.5 mm² with earth.
Ensure correct polarity (230 V - 50 Hz).
 &RQQHFWLQJ 4$& RXWVLGH VHQVRU DQG
4$$URRPVHQVRURSWLRQV
- Use the connectors supplied with the sensors.
- Wire up these connectors to the length required;
the polarity of the wires is not significant.
- Connect the sensors to the terminal block
(fig. 22).
 $GGLWLRQDOIXQFWLRQV
A modem function is only possible if a QAA70 is
connected.
The remote control is connected to the antifreeze in-
put (ST23) on the LGM 11.34 side and behaves as
a switch either shunting the antifreeze input or leav-
ing an open circuit across it.
&RPSO\ZLWKSURWHFWLRQFODVV,,,
Effects of the switch position:
- Switch closed (short-circuit): The QAA70 is set to
standby in the LGM (the QAA70 regime indicated
is cancelled).
- Switch open (open-circuit): No effect on the
QAA70 regime.
!
!

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the geminox THR Series and is the answer not in the manual?

geminox THR Series Specifications

General IconGeneral
Brandgeminox
ModelTHR Series
CategoryBoiler
LanguageEnglish

Related product manuals