EasyManuals Logo
Home>geminox>Boiler>THR Series

geminox THR Series User Manual

geminox THR Series
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image

23(5$7,21
When the winter/summer switch is set to the sum-
mer position, the regulator provides hot water only.
The temperature control knob becomes inactive; In
effect the heating flow temperature is regulated as a
function of the real outdoor temperature conditions.
This is achieved using the heating curves integrated
into the regulator itself.
The slope of this curve is preset to an average val-
ue, but can be corrected using the heating knob and
button C (both located on the control panel) to cor-
rect it to warmer or cooler (shifted parallel).
Once this parameter has been set, your heating sys-
tem becomes completely independent
1
and will pro-
duce ambient temperatures that are finely
calculated to give the optimum operating yield.
 0RGLI\LQJKHDWLQJSDUDPHWHUV
 )ORRUKHDWLQJ
The heating curve slope is factory-preset to 1.5 to
cater for heating by radiator.
This value needs to be changed to 0.8 when used
with floor heating:
- Press the three buttons A, B and C simultaneous-
ly until a IODVKLQJ/ appears on the display, fol-
lowed by a IODVKLQJ,,.
The slope has now been corrected. It is however
possible to refine the following parameters accord-
ing to the precise needs of the installation (see
§ 2.2.2.3 - III - OPERATION) by increasing or reduc-
ing the temperature setting by a few degrees.
 5DGLDWRUKHDWLQJ
The factory settings correspond to heating by radia-
tor. The characteristics of the building (e.g. insula-
tion, heating surface) may mean that the setting
need adjusting in order to obtain a higher or lower
level of heating. This involves modifying the heating
curve parameters (see § 2.2.2.3 - III - OPERA-
TION).
 0RGLI\LQJSDUDPHWHUV
Adjust the heating knob to the right to obtain a
warmer temperature setting (room temperature
warmer) (max. + 3 °C) and to the left for a cooler set-
ting (max. - 3 °C). Press button & until an )appears
on the display (about 3 s). The parameters have
now been adopted by the system.
If the radiator temperature setting needs to be in-
creased by more than 3 degrees, this operation can
be repeated, but first wait for 10 minutes to allow the
regulator time to register the new parameters prop-
erly. The inherent inertia in buildings and their heat-
ing systems means that it may take several hours to
react to a change, so it is better not to change this
parameter too often.
To return to the standard parameters, press the
three buttons $, % and & simultaneously until an /
appears on the display.
 7+5 ZLWK RXWVLGH WHPSHUDWXUH VHQVRU
DQGURRPVHQVRU
All the controls, settings, overrides and corrections
for heating flow/hot water temperatures (if optional
hot water tank included) can be carried out using the
room sensor.
 3ULQFLSOH
This version is designed to provide optimum com-
fort. As well as the functions linked to the outside
sensor described for the model above, the system
also has a room sensor.
This QAA70 room sensor provides the following
functions:
-
Compensation for ambient conditions.
- The ability to programme three daily periods for
heating or hot water.
- A easy programme override to switch the system
off either momentarily or for longer periods (e.g.
holidays).
1. The heating flow temperature varies automatically accor-
ding to the outside temperature.
6
O
R
S
H
0
10
20
30
40
50
60
70
80
90
100
20 15 10 5 0 -5 -10 -15 -20
2XWVLGHWHPSHUDWXUH&
%
R
L
O
H
U
V
H
W
S
R
L
Q
W
W
H
P
S
H
U
D
W
X
U
H
&
0,2
0,4
0,6
0,8
1
1,2
1,4
1,6
1,8
2
2,2
2,4
)LJ
)LJ

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the geminox THR Series and is the answer not in the manual?

geminox THR Series Specifications

General IconGeneral
Brandgeminox
ModelTHR Series
CategoryBoiler
LanguageEnglish

Related product manuals