33701 C MMG75D-100D Operating Manual 23
Section 3 - Operation
PRESTART CHECKLIST
Before starting the unit, all items in the prestart checklist must be completed. This checklist applies to both manual
and remote starting of the unit.
Read and understand ALL safety sections at the beginning of this manual.
Verify all maintenance procedures are up to date. For more information, see General Maintenance
and Basic Maintenance Schedule.
The unit must be level.
The unit must be dry. Verify there is no water inside, on, or near the unit; dry if needed.
For grounding requirements, follow any local, state, or National Electrical Code (NEC) guidelines.
Verify the Control Power switch is OFF (O).
Verify all circuit breakers are OFF (O).
Inspect all electrical cords; repair or replace any that are cut, worn, or bare.
Verify oil, coolant, and fuel levels are correct, per the engine manufacturer manual.
Verify battery connections are secure.
Turn the battery disconnect switch on, if equipped.
Check the engine fan belt tension and condition.
Check the engine fan belt guard.
Check the engine exhaust system for loose or rusted components.
Verify all covers are in place and secure.
Verify all electrical connections at the connection lugs, if equipped, are tight and wired correctly.
Verify the voltage selector switch is set to the desired voltage and locked.
Verify the emergency stop switch is pulled out.
Verify the radiator and surrounding shroud are clear of debris.
MANUALLY STARTING THE UNIT
All units equipped with the Power Zone™ controller will initially start up in Stop mode. Use the following procedure
to start the generator in Manual mode:
1. Move the Control Power switch to ON (I).
DANGER
CARBON MONOXIDE: USING A GENERATOR INDOORS CAN KILL YOU IN MINUTES.
2. The LCD window will show the prestart diagnosis and the controller will load the unit management software.
Figure 3-1. Prestart Screen
00414
82%
Image File Transer...
TM

Table of Contents

Other manuals for Generac Power Systems MAGNUM MMG75D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Generac Power Systems MAGNUM MMG75D and is the answer not in the manual?

Generac Power Systems MAGNUM MMG75D Specifications

General IconGeneral
BrandGenerac Power Systems
ModelMAGNUM MMG75D
CategoryPortable Generator
LanguageEnglish

Related product manuals