2
LoadState: OFF Load in “ON” or “OFF” state
LoadCrt: 0A Load current
BatSoc: 100% Remaining battery capacity
DevTemp: 27°C Controller temperature
3
ChagPower: 0W
Charging power
LoadPower: 0W Discharging power
MinBatVol: 12.5V The current day’s min. battery voltage
MaxBatVol: 13.0V The current day's max. battery voltage
4
Fault: NULL
Controller error codes:
BAT-LDV, over-discharge
BAT-OVD, over-voltage
BAT-UVW, under-voltage warning
L-SHTCRT, load short-circuit
L-OVRCRT, load over-current
DEV-OVT, internal over-temperature
BAT-OVT, battery over-temperature
P-OVP, solar panel overpower
P-SHTCRT, solar panel short-circuit
P-OC-OVD, solar panel over-voltage
P-MP-OVD, solar panel working over-voltage
P-REVERSE, solar panel reverse-connection
6.1.6 SYSTEM PARAMETER SETTINGS
AUTO/SLD
BST : 14.4V
LVD : 11.0V
SET
Setting icon
System voltage indication
Battery type indication
Boost charging voltage 14.4V
Over-discharge voltage 11.0V
The Parameters Setting page will have a brief summary of the parameters already set in this menu:
• AUTO: the battery voltage is the automatic recognition system
• SLD: battery type is sealed lead acid battery;
• BST: charging voltage is 14.4V*n
• LVD: over-discharge voltage is 11.0V*n
• Tap to enter into the following submenus.
OPERATION AND DISPLAY