4.5 CHECKING THE ELECTRICAL CONNECTION
1. Check if the AC or DC wire is loose.
2. Check if the earth wire is reliable grounding.
3. Check if the waterproof covers of BMS and Meter port is fasten.
Caution: Maintenance cycle is once half a year.
4. Please use torque wrench to tighten the AC and battery terminal wiring connection
once a year; followed 2.4 torque instruction.
OTHERS
Environment Condition Ambient Temperature Relative Humidity Applied to
Environment Category Definition
Pollution Degree Definition
Outdoor
Indoor Unconditioned
Indoor Conditioned
Pollution Degree Ⅰ
Pollution Degree Ⅱ
Pollution Degree Ⅲ
Pollution Degree Ⅳ
-20~50℃
4%~100%
PD3
PD3
PD2
5%~95%
5%~85%
-20~50℃
0~40℃
No pollution or only dry, non-conductive pollution occurs. The pollution has no infuence
Persistent conductive pollution occurs, for example, the pollution caused by conductive dust, rain and snow.
Normally only non-conductive pollution occurs. Ooccasionally, however, a temporary conductivity caused by
condensation must be expected.
Conductive pollution occurs, or dry, non-conductive pollution occurs, which becomes conductive due to
condensation, which is expected.

Other manuals for Goodwe EH Plus Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Goodwe EH Plus Series and is the answer not in the manual?

Goodwe EH Plus Series Specifications

General IconGeneral
BrandGoodwe
ModelEH Plus Series
CategoryInverter
LanguageEnglish

Related product manuals