42
09 Maintenance
For Re-
view
User Manual V1.0-2023-03-20
9 Maintenance
9.1 Power OFF the Inverter
DANGER
• Power o the inverter before operations and maintenance. Otherwise, the inverter may be
damaged or electric shocks may occur.
• Delayed discharge. Wait until the components are discharged after power o.
Step 1 Issue a command to the inverter for disconnecting the grid via SolarGo APP
Step 2 Turn o the AC breaker between the inverter and the utility grid.
Step 3 Turn o the DC switch of the inverter.
9.2 Removing the Inverter
WARNING
• Make sure that the inverter is powered o.
• Wear proper PPE before any operations.
Step 1 Disconnect all the cables, including DC input cables, AC output cables, communication
cables, the communication module, and PE cables.
Step 2 Remove the inverter from the mounting plate.
Step 3 Remove the mounting plate.
Step 4 Store the inverter properly. If the inverter needs to be used later, ensure that the storage
conditions meet the requirements.
9.3 Disposing of the Inverter
If the inverter cannot work anymore, dispose of it according to the local disposal
requirements for electrical equipment waste. The inverter cannot be disposed of together
with household waste.