Before Beginning Repair
3A1570V 15
Before Beginning Repair
1. Flush if necessary. See Flushing, page 17.
2. Turn main heater power OFF .
3. Follow the Pressure Relief Procedure.
Pressure Relief Procedure
NOTE: The Fusion AP gun is shown.
1. Turn off feed pumps and agitator if used.
2. Park component A pump. Follow Park, page 16.
3. Close the air inlet valve.
4. Engage gun piston safety lock.
5. Close gun fluid inlet valves A and B.
6. Close pump inlet supply valves.
Repairing this equipment requires access to parts
that may cause electric shock or other serious injury
if work is not performed properly. Electrical
troubleshooting must be done by a qualified
electrician. Be sure to shut off all power to equipment
and lock out power at the source before repairing.