EasyManuals Logo
Home>Gree>Controller>XK49

Gree XK49 User Manual

Gree XK49
27 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
Wired Controller XK49
16
P31
High ceiling
installation*
00: installation
height of standard
ceiling
01: installation
height of high
ceiling
00
Only applicable to cassette units
P33
Set Timer
00: general timer
01: clock timer
00
This setting is valid when it is used
to control one (multiple) indoor unit
(s) with other wired controller (s)
with timer function.
P34
Clock Timer
repetition is
valid
00: once
01: repeat everyday
00
This setting is valid when it is used
to control one (multiple) indoor unit
(s) with other wired controller (s)
with timer function, and when the
unit timer function is set “Clock
Timer”.
P37
Cooling setting
temperature
under auto
mode
17°C~30°C(63°F~8
F)
25°C(77°
F)
When the temperature unit is°C,
cooling setting temperature minus
heating setting temperature1°C.
When the temperature unit is°F,
cooling setting temperature minus
heating setting temperature2°F.
P38
Heating setting
temperature
under auto
mode
16°C~29°C(61°F~8
F)
20°C(68°
F)
P43
Set priority
operation
00: normal
operation
01: priority
operation
00
When power supply is insufficient,
the indoor units which are set to
priority operation can operate, while
other indoor units are forced to be
turned off.
P46
Clear Filter
Clean
accumulated
time
00: do not clear
01: clear
00
Note: The filter-clean reminder
function is not available for this
wired controller.
P49
Opening angle
of indoor unit
air-return plate*
01: angle 1(25°)
02: angle 2(30°)
03: angle 3(35°)
01
Only applicable to units with
air-return plate
P50
Air outlet
temperature
setting for
Fresh Air
Indoor Unit in
cooling*
16°C30°C
18°C
Only applicable to Fresh Air Indoor
Unit.
P51
Air outlet
temperature
setting for
Fresh Air
Indoor Unit in
heating*
16°C30°C
22°C
Only applicable to Fresh Air Indoor
Unit.
P54
Union setting of
Fresh Air
Indoor Unit*
00: without union
control
01: with union
control
00
After union function is set, Fresh Air
Indoor Unit will be turned on/off
following the on/off status of
common indoor unit. Besides, Fresh
Air Indoor Unit can also be turned
on/off manually.
Note: only applicable to Fresh Air
Indoor Unit.

Questions and Answers: