37
SECTION 7. TROUBLESHOOTING
! WARNING: For qualied service personnel ONLY!
This procedure assumes that the lter system is operating. Jumper wires are used for system checkout
only. Remove all jumper wires following system checkout or damage to heater may result.
From page 36.
Does the main burner re?
Does the main burner re?
Replace the system switch.
Does the main burner re?
Does the main burner re?
Remove jumper from thermostat
terminals.
Jump across each of the high
limits.
Jump across system switch
terminals.
Jump across each of the high
temperature limiter terminals.
Be sure the manual reset
high temperature limiter is not
thrown.
Replace the high temperature
limiter switch that caused the
heater to re.
Call Hayward Technical Service:
Pomona, CA (909) 594-1600
Elizabeth, NJ (908) 351-5400.
Replace the high limit that caused
the heater to re.
NO
NO
NO
YES
YES
YES
YES

Table of Contents

Other manuals for Hayward H250

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hayward H250 and is the answer not in the manual?

Hayward H250 Specifications

General IconGeneral
ModelH250
CategorySwimming Pool Heater
Thermal Efficiency80%
Maximum Working Pressure50 psi
BTU Input250, 000 BTU
Heat ExchangerCupro-Nickel
Ignition TypeDirect Spark
BTU Output200, 000 BTU/hr
IgnitionDirect Spark Ignition

Related product manuals