Pocket Series User Manual
13
Chapter 4 Temperature Measurement
The thermography (temperature measurement) function provides the
real-time temperature of the scene and display it on the left of your
screen. The thermography function is turned on by default.
4.1 Set Measurement Parameters
You can set measurement parameters to improve the accuracy of
temperature measurement.
Steps
1. Go to Settings ā Measurement Settings.
2. Set the Temperature Range, Emissivity, etc.
Temperature Range
Select the temperature measurement range. The device can detect
the temperature and switch thermography range automatically in
Auto Switch mode.
Emissivity
Refer to Common Material Emissivity Reference to set the emissivity
of your target.
Reflection Temperature
If any object (not the target) of high temperature is in the scene, and
the target emissivity is low, set the reflection temperature as the high
temperature to correct the thermography effect.
Distance
The distance between the target and the device. You can customize
the target distance or select the target distance as Near, Middle, or
Far.
Humidity