Access Control Terminal·User Manual
86
3) Set the sector ID.
4) Click Select Device to select a device in the pop-up window for anti-passing back
authentication.
5) In the Set Card Reader area, check the checkboxes in the Enable Anti-passing Back
column to select the entrance card reader and the exit card reader.
6) Click Save to save the settings.
Notes:
Up to one entrance carder and one exit card reader should be checked.
Up to 64 controllers with anti-passing back function can be added.
It supports M1 card at present and the sector cannot be encrypted. For details
about sector encryption, refers to 7.4.8 M1 Card Encryption.
Based on Network
Note: Authenticate the anti-passing back according to the entrance and exit information
on the card reader.
1) Select Based on Network as the anti-passing back mode in the drop-down list.
2) Select Entrance/Exit Anti-passing Back as the rule.
3) Select the server in the dropdown list for judging the anti-passing back.
4) (Optional) You can click Delete Record and select the card in the pop-up window to
delete the card swiping information in all devices.
5) Click Select Device to select a device in the pop-up window for anti-passing back
authentication.
6) In the Set Card Reader area, check the checkboxes in the Enable Anti-passing Back
column to select the entrance card reader and the exit card reader.
7) Click Save to save the settings.
Notes:
Up to one entrance carder and one exit card reader should be checked.
Up to 64 controllers with anti-passing back function can be added.
Up to 5000 cards swiping records can be stored in the selected server.
7.8.7 Multi-door Interlocking
Purpose:
You can set the multi-door interlocking between multiple doors of the same access control device.
To open one of the doors, other doors must keep closed. That means in the interlocking combined
door group, up to one door can be opened at the same time.
Notes:
The Multi-door Interlocking function is only supported by the access control device which has
more than one access control points (doors).
Either the anti-passing back or multi-door interlocking function can be configured for an access
control device at the same time.
Steps:

Table of Contents

Other manuals for HIKVISION DS-K2802

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-K2802 and is the answer not in the manual?

HIKVISION DS-K2802 Specifications

General IconGeneral
Product typeAccess controller
CertificationCE, FCC
CompatibilityWiegand
Mounting typeWall
Product colorBlack
Brand compatibilityHikvision
Operating temperature (T-T)-20 - 65 °C
Quantity per pack1 pc(s)
Weight and Dimensions IconWeight and Dimensions
Depth285 mm
Width237 mm
Height69 mm